AQ301 Industrial Steam Boiler Water Dosing and Management


Features and Benefits



              Keeps Boilers scale and corrosion free

              Lower operating costs

              Ensures correct chemical levels at all times

              Reduced man hours in system operation and tests

              Easily reconfigured for new chemical suppliers

              Download PDF of Specifications>


Designed for industrial steam boiler installations up to 100 bar, the AQ300 accurately monitors the boiler and feed water conditions. It injects exactly the required amount of chemicals and provides auto surface blow down control. It keeps the entire plant within the desired chemical limits, 24 hours a day, regardless of load.

The units can be fitted with a mixture of pumps of pumps and programmed for different pressure Boilers and water treatment chemicals.

The system includes pH, conductivity, dissolved oxygen, temperature probes, data commumications unit with software, feed flow meters, auto blow down valves, test kit and dosing pumps complete with suction assemblies and low level alarms.

The software provides for continuous display of all important readings and pre-formatted ?Management Reports? which outputs a summary of average readings for any period requested. The unit can be linked to other AQUANET systems and all readings are displayed on one monitor. The system is pre-configured for each installation and a choice of coolers, pumps, flow meters and blow down valves are available depending on requirements. Installation can be carried out by the owners staff, sub-contractor or AQUANET personnel.


Specifications
Dimensions (W) x (H) x (D) mm
1020 x 490 x 250
(assembled c/w chemical drums)

The instrumentation is housed
in a split steel cabinet with hinged lockable doors.


The left hand section constructed of stainless steel,
houses the sampling system and probes.


The right hand section houses signal conditioning,
control and the communications interface.


















Probes


pH
Automatic temperature compensation
Sealed Reference cell
Resolution 0.5% FSD>


Conductivity
Range0-600 Mhos
(other ranges available)
Automatic temperature compensation
Resolution 0.5% FSD


Dissolved Oxygen
:Range 2.5 mg/l
Automatic temperature compensation
Resolution 0.5% FSD


Feed Temperature
Stainless steel pocketed probe
0-110?C scaled as 4-20 mA signal










Flow Meters
Mechanical to suit pipe work.
OR Ultrasonic Flow Meters (Non penetrating).
Clamps onto outside of existing pipe work.
Transducer maximum operating temperature 130?C

Blowdown Valves
Mechanically operated to 32 bar Or
Pneumatic, Rated 100 bar to suit application.


Dosing Pumps
Diaphragm Pulse
1 litre/hr 17 bar max, polypropylene head.
Teflon coated diaphragm.


GSM Interface(OPTION)
Allows selectable alarms to be sent to an
engineers or control room telephone.


Communications and Monitoring (OPTION)
AQUANET software
compatibility for monitoring, logging
and display. RS422 differential
line drivers CRC protected









Additional standard features Flushing water system with flow monitoring. Dosing pump manual speed control Dosing pump vent system, returns chemical to drum (No spillage) Fuse failure alarms Auto probe calibration on the unit.